Air resistance of paper (Gurley method), Test Method T 460 om-11



Please Note: This document will be available in PDF format in the "My Electronic Documents" link on the home page once your order has been completed. Please make sure you have the latest version of Acrobat Reader. Click on the Acrobat Reader icon to check for the latest version, it’s FREE. To print a hardcopy of a PDF file correctly you must have a postscript printer. If you are not sure if your printer is a postscript printer please refer to your owner’s manual.

This method is used to measure the air resistance of approximately 6.45 sq. cm. (l sq. in.) circular area of paper using a pressure differential of 1.22 kPa. The recommended range of the liquid column instrument is from 5 to 1800 seconds per 100 mL cylinder displacement. For more impermeable papers the time requirements become so excessive that other techniques are preferable.

This method measures the volume of air that passes through the test specimen, along with any possible leakage of air across the surface; therefore it is unsuitable for paper or paperboards which cannot be securely clamped so as to avoid significant surface and/or edge leakage.

For a similar method of measuring air resistance that tests paper at a higher pressure (approx. 3 kPa), and has higher resolution in measuring smaller air volumes, refer to TAPPI T 536. For a method of measuring air permeance at pressures up to 9.85 kPa, using both smaller and larger test areas, refer to TAPPI T 547.