Inventory audit notice: TAPPI Press orders will not be processed from August 21–28 during our fiscal year-end inventory audit. Orders placed during this time will ship starting August 31, in the order received. Normal payment processing also resumes August 31.

Thanks for your patience — this helps us serve our members better.

Search

Use the search bar or filters below to find any TAPPI product or publication.

Showing 11–20 of 29 results (Duration : 0.01 seconds)
Journal articles
Open Access
Lee bingham heads sca tissue in north america, TAPPI JOURNAL, July 2001, Vol. 84(7)

Lee bingham heads sca tissue in north america, TAPPI JOURNAL, July 2001, Vol. 84(7)

Journal articles
Open Access
Prioritization for an r&t program: tools that help to achieve consensus, TAPPI JOURNAL, July 2001, Vol. 84(7)

Prioritization for an r&t program: tools that help to achieve consensus, TAPPI JOURNAL, July 2001, Vol. 84(7)

Journal articles
Open Access
Effects of creping conditions on surface softness of tissue paper - application of sled method, TAPPI JOURNAL, December 2000, Vol. 83(12)

Effects of creping conditions on surface softness of tissue paper - application of sled method, TAPPI JOURNAL, December 2000, Vol. 83(12)

Journal articles
Magazine articles
Open Access
Enhancing tissue wet pressing performance and dry end material efficiency for cost savings, TAPPI Journal May 2024

ABSTRACT: The steadily growing global tissue paper demand lays a foundation for new technologies targeting tissue production optimization, as well as improved material and time efficiency. Tissue making is an especially energy-intensive field of paper industry, creating unique demands for performance in wet pressing and drying processes to cut energy usage. Intelligent roll solutions offer new tools for tissue making to achieve these goals. These tools aim at improving press nip, moisture, and tension profiles; reeling nip and parent roll hardness profiles; rewinder runnability; and end product web handling characteristics in converting. Intelligent rolls can be utilized in all the main processes and positions on tissue production lines. With these tools, production cost reductions and energy savings can be obtained by optimizing the press nip-to-Yankee cylinder contact, avoiding moisture profile errors requiring overdrying with the Yankee hood and reducing reeling/winding broke under low nip load conditions typical to tissue windups. The intelligent roll system consists of a helically mounted force or temperature sensors, roll covers, measurement electronics, digital radio transmission, and a receiver system connected to a user interface or the mill automation system. What distinguishes these implementations is that no layout changes or added external measurement devices are required, helping to fit into compact tissue machine environments, regardless of the equipment type • traditional, hybrid, or through-air drying (TAD) concept. In tissue processing equipment, the optimal positions for these rolls are press nip rollers, reeling cylinders, rewinder or converting line paper lead rolls, or rewinder winding drums. In addition to these, temperature profile measurements are utilized, with the main application being the sheet temperature profile detection after Yankee drying for moisture profile and drying process optimization.

Journal articles
Open Access
Tissue roll handling with an agvs, TAPPI JOURNAL, February 2000, Vol. 83(2)

Tissue roll handling with an agvs, TAPPI JOURNAL, February 2000, Vol. 83(2)

Journal articles
Open Access
Effects of creping conditions on surface softness of tissue paper - application of sled method, TAPPI JOURNAL, December 2000, Vol. 83(12)

Effects of creping conditions on surface softness of tissue paper - application of sled method, TAPPI JOURNAL, December 2000, Vol. 83(12)

Journal articles
Magazine articles
Open Access
Quantification of the degree of preference for different tissue products based on a hand-felt tissue test panel, TAPPI Journal May 2023

ABSTRACT: In this study, we successfully established a quantification model to determine the preference (PF) for different tissue products based on the results of a hand-felt tissue testing panel. The panel ascertained that products designed with four-ply tissues provided higher total tensile strength (TTS) and hand-felt surface softness (HSS) than did those of the three-ply, two-ply, and single-ply products.When practically tested with a tissue softness analyzer (TSA), the four-ply tissue product had a softness (TSA-HF) advantage; however, in human panel tests, more than half of the participants could not be sure of the hand-felt bulk softness (HBS) of the four-ply tissue product. This was mainly because when using the four-ply tissue, the hand-held test pad gave an overall perception distinctly different from those of the hand-held two- or three-ply products, which also differed from the flattened state of test pieces used in the instrumental softness tests. Users could distinctly feel that a product was safer (better TTS) and more comfortable (higher hand-held surface softness). Thus, the four-ply tissue product was accorded a higher preference.

Journal articles
Magazine articles
Open Access
Measurement of the dynamics of fluid sorption for tissue papers, TAPPI Journal July 2019

ABSTRACT: Liquid absorption ability belongs to the most important features of tissue papers. Due to non-homo-geneous internal and superficial structures, precise and fast evaluation of this property is challenging. The main aim of the presented research was to design an experimental device dedicated to the measurement of the kinetics of wetting phenomenon for tissue papers. The second aim was to evaluate whether it was possible to use image analysis for more precise characterization of liquid absorption properties of tissue paper. The obtained results showed that the method used, based on image analysis supported by gravimetric methods, proved to efficiently and quantitatively characterize the dynamics of liquid absorption for tissue papers. Supplementary parameters such as absorption anisotropy and in-plane velocity were obtained. Different experi-mental results were obtained for various tissue paper grades. Furthermore, water absorption capacity calculated from image analysis data correlated with results obtained according to the standard method EN ISO 12625-8:2010 “Tissue paper and tissue products—Part 8: Water-absorption time and water-absorption capacity, basket-immersion test method.” Hence, the presented device quantitatively characterizes and discriminates water absorption phenom-enon for tissue papers.

Journal articles
Magazine articles
Open Access
An evaluation of household tissue softness, TAPPI Journal February 2021

ABSTRACT: This study extends our 2019 paper, a study of the softness of household tissues using a tissue softness analyzer (TSA) and hand-felt panels. It revisits the softness theory of Holger Hollmark by applying a reciprocal matrix approach to measure sheet bulk softness and surface softness, and then make comparisons with the results obtained using a TSA instrument. We ascertained that there was a high correlation of R=0.904 between panel-corrected hand-felt (CHF) softness and TSA softness (TSA-HF); and a low correlation of R=-0.678 between panel-corrected hand-felt surface softness (CHSS) and TSA smoothness (TS-750). Three hunches about TSA measurements were confirmed: 1) Hollmark’s theory was confirmed by a high correlation coefficient (R=0.895) between CHF and CHSS softness, indicating that the two parameters are mutually dependent; 2) TS-750 differs from CHSS and has partial influence on TSA-HF results with a correlation of R = -0.510; and 3) although TS-750 has only limited influences on TSA-HF, further opportunities for their application can be provided using pertinent regression equations.

Journal articles
Open Access
Through-air drying of tissue and towel grades, TAPPI JOURNAL, April 1999, Vol. 82(4)

Through-air drying of tissue and towel grades, TAPPI JOURNAL, April 1999, Vol. 82(4)