Measurement of the dynamics of fluid sorption for tissue papers, TAPPI Journal July 2019

ABSTRACT: Liquid absorption ability belongs to the most important features of tissue papers. Due to non-homo-geneous internal and superficial structures, precise and fast evaluation of this property is challenging. The main aim of the presented research was to design an experimental device dedicated to the measurement of the kinetics of wetting phenomenon for tissue papers. The second aim was to evaluate whether it was possible to use image analysis for more precise characterization of liquid absorption properties of tissue paper. The obtained results showed that the method used, based on image analysis supported by gravimetric methods, proved to efficiently and quantitatively characterize the dynamics of liquid absorption for tissue papers. Supplementary parameters such as absorption anisotropy and in-plane velocity were obtained. Different experi-mental results were obtained for various tissue paper grades. Furthermore, water absorption capacity calculated from image analysis data correlated with results obtained according to the standard method EN ISO 12625-8:2010 “Tissue paper and tissue products—Part 8: Water-absorption time and water-absorption capacity, basket-immersion test method.” Hence, the presented device quantitatively characterizes and discriminates water absorption phenom-enon for tissue papers.

Journal articles
Magazine articles
Open Access
An evaluation of household tissue softness, TAPPI Journal February 2021

ABSTRACT: This study extends our 2019 paper, a study of the softness of household tissues using a tissue softness analyzer (TSA) and hand-felt panels. It revisits the softness theory of Holger Hollmark by applying a reciprocal matrix approach to measure sheet bulk softness and surface softness, and then make comparisons with the results obtained using a TSA instrument. We ascertained that there was a high correlation of R=0.904 between panel-corrected hand-felt (CHF) softness and TSA softness (TSA-HF); and a low correlation of R=-0.678 between panel-corrected hand-felt surface softness (CHSS) and TSA smoothness (TS-750). Three hunches about TSA measurements were confirmed: 1) Hollmark’s theory was confirmed by a high correlation coefficient (R=0.895) between CHF and CHSS softness, indicating that the two parameters are mutually dependent; 2) TS-750 differs from CHSS and has partial influence on TSA-HF results with a correlation of R = -0.510; and 3) although TS-750 has only limited influences on TSA-HF, further opportunities for their application can be provided using pertinent regression equations.

Journal articles
Magazine articles
Open Access
Rheological characterization of tack and viscoelasticity of compositions of crepe coating used in the Yankee dryer, TAPPI Journal November 2019

ABSTRACT: The vast majority of tissue production uses creping to achieve the required set of properties on the base sheet. The Yankee coating helps to develop the desired crepe that in turn determines properties such as bulk and softness. The adhesion of the sheet to the Yankee surface is a very important characteristic to consider in achieving the desired crepe. The coating mix usually consists of the adhesive, modifier, and release. A good combination of these components is essential to achieving the desired properties of the tissue or towel, which often are determined by trials on the machine that can be time consuming and lead to costly rejects. In this paper, five compo-sitions of an industrial Yankee coating adhesive, modifier, and release were examined rheologically. The weight ratio of the adhesive was kept constant at 30% in all five compositions and the modifier and release ratios were varied. The normal force and work done by the different compositions have been shown at various temperatures simulating that of the Yankee surface, and the oscillatory test was carried out to explain the linear and nonlinear viscoelastic characteristic of the optimal coating composition.

Journal articles
Magazine articles
Open Access
Rheological characterization of tack and viscoelasticity of compositions of crepe coating used in the Yankee dryer, TAPPI Journal November 2019

ABSTRACT: The vast majority of tissue production uses creping to achieve the required set of properties on the base sheet. The Yankee coating helps to develop the desired crepe that in turn determines properties such as bulk and softness. The adhesion of the sheet to the Yankee surface is a very important characteristic to consider in achieving the desired crepe. The coating mix usually consists of the adhesive, modifier, and release. A good combination of these components is essential to achieving the desired properties of the tissue or towel, which often are determined by trials on the machine that can be time consuming and lead to costly rejects. In this paper, five compo-sitions of an industrial Yankee coating adhesive, modifier, and release were examined rheologically. The weight ratio of the adhesive was kept constant at 30% in all five compositions and the modifier and release ratios were varied. The normal force and work done by the different compositions have been shown at various temperatures simulating that of the Yankee surface, and the oscillatory test was carried out to explain the linear and nonlinear viscoelastic characteristic of the optimal coating composition.

Journal articles
Magazine articles
Open Access
Quantification of the degree of preference for different tissue products based on a hand-felt tissue test panel, TAPPI Journal May 2023

ABSTRACT: In this study, we successfully established a quantification model to determine the preference (PF) for different tissue products based on the results of a hand-felt tissue testing panel. The panel ascertained that products designed with four-ply tissues provided higher total tensile strength (TTS) and hand-felt surface softness (HSS) than did those of the three-ply, two-ply, and single-ply products.When practically tested with a tissue softness analyzer (TSA), the four-ply tissue product had a softness (TSA-HF) advantage; however, in human panel tests, more than half of the participants could not be sure of the hand-felt bulk softness (HBS) of the four-ply tissue product. This was mainly because when using the four-ply tissue, the hand-held test pad gave an overall perception distinctly different from those of the hand-held two- or three-ply products, which also differed from the flattened state of test pieces used in the instrumental softness tests. Users could distinctly feel that a product was safer (better TTS) and more comfortable (higher hand-held surface softness). Thus, the four-ply tissue product was accorded a higher preference.

Journal articles
Magazine articles
Open Access
Visual discrimination of hygiene tissue softness in the abse

Visual discrimination of hygiene tissue softness in the absence of haptic feedback, TAPPI JOURNAL August 2017